Component Tests and General Diagnostics
INPUT/TURBINE SPEED SENSOR INSPECTIONResistance Inspection
1. Measure the resistance between the terminals of the input/turbine speed sensor.
Resistance 250 - 600 ohms (ATF temperature: -40 - 160°C (-40 - 320°F))
^ If not as specified, replace the input/turbine speed sensor.