Vacuum Chamber Check Valve
VACUUM CHAMBER CHECK VALVE INSPECTION1. Remove the vacuum chamber check valve.
2. Blow through port A and verify that the air flows from port B.
- If not as specified, replace the vacuum chamber check valve.
3. Blow through port B and verify that the air does not flow from port A.
- If not as specified, replace the vacuum chamber check valve.