Power Trunk / Liftgate Lock Actuator: Testing and Inspection
TRUNK LID LOCK ACTUATOR INSPECTION1. Disconnect the negative battery cable.
2. Disconnect trunk lid lock actuator.
3. Apply battery positive voltage to the trunk lid lock actuator terminals and inspect the operation of the trunk lid lock actuator.
- If not as specified replace the trunk lid lock.