Variable Induction Position Sensor: Testing and Inspection
VARIABLE TUMBLE CONTROL SYSTEM (VTCS) VACUUM SWITCH INSPECTIONOperation Inspection
1. Disconnect the negative battery cable.
2. Disconnect the vacuum hose from the VTCS vacuum switch.
3. Connect a vacuum pump to the VTCS vacuum switch.
4. Apply vacuum slowly and verify that continuity between the VTCS vacuum switch terminals changes as indicated in the table using an ohmmeter.
- If not as specified, replace the VTCS vacuum switch.
- If VTCS vacuum switch is okay but PID value is out of specification, perform the "Circuit Open/Short Inspection".
5. Reconnect the VTCS vacuum switch connector.
Circuit Open/Short Inspection
Open circuit
- If there is no continuity and the circuit is open, repair or replace the harness.
- Power circuit (VTCS vacuum switch connector terminal A and PCM connector terminal 4J through common connector)
- GND circuit (VTCS vacuum switch connector terminal B and GND through common connector)
Short circuit
- If there is no continuity and the circuit is shorted, repair or replace the harness.
- VTCS vacuum switch connector terminal A and PCM connector terminal 4J through common connector to GND