Hydraulic Lash Adjuster (HLA) Inspection
HYDRAULIC LASH ADJUSTER (HLA) INSPECTION1. Measure the diameter of each HLA bore.
Standard diameter
16.018-16.057 mm (0.63063-0.63216 in)
2. Measure the diameter of each HLA.
Standard diameter
15.988-16.000 mm (0.62945-0.62992 in)
3. Calculate the clearance between the HLA and the related HLA bores.
^ If the clearance exceeds the maximum clearance, replace the cylinder head or the HLA.
Standard clearance
0.018-0.069 mm (0.0008-0.0027 in)
Maximum clearance
0.16 mm (0.0063 in)