Knock Sensor: Testing and Inspection
KNOCK SENSOR (KS) INSPECTIONNOTE: Perform the following inspection only when directed.
Resistance Inspection
1. Disconnect the negative battery cable.
2. Disconnect the KS connector.
3. Measure the resistance between the KS terminals A and B using an ohmmeter.
- If the KS is okay, but the PID value is out of specification, perform the "Circuit Open/Short Inspection".
- If not as specified, replace the KS.
Specification: Approx. 4.87 megohms (20°C {68°F})
Circuit Open/Short Inspection
1. Disconnect the PCM connector.
2. Inspect the following harness for open or short circuit. (Continuity check)
Open circuit
- KS terminal B (harness-side) and PCM terminal 31 (harness-side)
- KS terminal A (harness-side) and PCM terminal 4 (harness-side)
Short circuit
- KS terminal A (harness-side) and power supply
- KS terminal A (harness-side) and body GND
- KS terminal B (harness-side) and power supply
- KS terminal B (harness-side) and body GND