Operation CHARM: Car repair manuals for everyone.

Connectors

CONNECTORS




Data link connector

- Insert the probe into the terminal when connecting a jumper wire to the data link connector.

CAUTION: Inserting a jumper wire probe into the data link connector terminal may damage the terminal.

Disconnecting connectors




- When disconnecting connector, grasp the connectors, not the wires.




- Connectors can be disconnected by pressing or pulling the lock lever as shown.

Locking connector




- When locking connectors, listen for a click indicating they are securely locked.

Inspection




- When a tester is used to inspect for continuity or measuring voltage, insert the tester probe from the wiring harness side.




- Inspect the terminals of waterproof connectors from the connector side since they cannot be accessed from the wiring harness side.

CAUTION: To prevent damage to the terminal, wrap a thin wire around the tester probe before inserting into terminal.