Oscilloscope Patterns and Waveforms
Inspection Using An Oscilloscope (Reference)CMP sensor signal
(+)
PCM terminals
- CMP sensor (left bank): 58 (+) - 25 (-)
- CMP sensor (right bank): 85 (+) - 25 (-)
Oscilloscope setting
- 1 V/DIV (Y), 20 ms/DIV (X), DC range
Vehicle condition
- Idle after warm up (no load)
(-)
PCM terminals
- CMP sensor (left bank): 59 (+) - 25 (-)
- CMP sensor (right bank): 86 (+) - 25 (-)
Oscilloscope setting
- 1 V/DIV (Y), 20 ms/DIV (X), DC range
Vehicle condition
- Idle after warm up (no load)