Refrigerant Pressure Check
REFRIGERANT PRESSURE CHECK1. Connect the manifold gauge.
2. Start the engine and after it is warmed up, run it at a constant 1,500 rpm.
3. Set the fan switch to 4th speed.
4. Turn the A/C switch on.
5. Set to RECIRCULATE mode.
6. Set the temperature control to MAX COLD.
7. Set to VENT mode.
8. Close all the doors and all the windows.
9. Measure the manifold gauge reading and ambient temperature
10. Verify that the high and low pressure readings are within each shaded zone
- If there is any malfunction, inspect the refrigerant system according to the troubleshooting chart.
REFRIGERANT RECOVERY
WARNING: Avoid breathing air conditioning refrigerant or lubricant vapor. Exposure may irritate eyes, nose and throat. Also, due to environmental concerns, use service equipment certified to meet the requirements of SAE J2210 (R-134a recycling equipment) when draining R-134a from the air conditioning system. If accidental system discharge occurs, ventilate work area before resuming service.
1. Connect an R-134a recovery/recycling/recharging device to the vehicle and follow the device manufacturer's instructions