Description of On-Board Diagnostics
OBD-II PENDING TROUBLE CODE- These appear when a problem is detected in a monitored system. The code for a failed system is stored in the PCM memory in the first drive cycle. This code is called the pending code. If the problem is not found in a second drive cycle, the PCM judges that the system returned to normal or the problem was mistakenly detected, and deletes the pending code. If the problem is found in a second drive cycle too, the PCM judges that the system has failed, and the DTC is stored.
OBD-II FREEZE FRAME DATA
- This is the technical data which indicates the engine condition at the time of the first malfunction. This data will remain in the memory even if another emission-related DTC is stored, with the exception of Fuel system or Misfire DTCs. Once freeze frame data for Fuel system or Misfire DTC is stored, it will overwrite any previous data and the freeze frame will not be overwritten again.
OBD-II ON-BOARD SYSTEM READINESS TEST
- This shows the OBD-II systems operating status. If any monitor function is incomplete, WDS or equivalent will identify which monitor function has not been completed. The Fuel system, Misfire and CCM are continuous monitoring-type functions. The HO2S, Thermostat, AIR system, Catalyst and EVAP system will be monitored under drive cycles. The OBD-II diagnostic system is initialized by performing the DTC cancellation procedure or disconnecting the negative battery cable.
OBD-II DIAGNOSTIC MONITORING TEST RESULT
- The results from the technical data of the intermittent monitor system are used to determine whether the system is normal or not. They also display the system thresholds and diagnostic results. The intermittent monitor system monitors the HO2S, Thermostat, AIR system, Catalyst and EVAP system
OBD-II READ/CLEAR DIAGNOSTIC TEST RESULT
- This retrieves all stored DTCs in the PCM and clears the on-board readiness test results, freeze frame data, DTC, diagnostic monitoring test results and pending trouble code.
OBD-II PARAMETER IDENTIFICATION (PID) ACCESS
- The PID mode allows access to certain data values, analog and digital inputs and outputs, calculated values and system status information. Since the PID values for output devices are the PCM internal data values, inspect each device to identify which output devices are malfunctioning.