Liftgate Adjustment

LIFTGATE ADJUSTMENT

1. Measure the gap and height difference between the liftgate and the body.




2. Loosen the liftgate hinge installation nuts and adjust the liftgate.
- If necessary, loosen the liftgate lock striker installation bolts and adjust the liftgate.

Standard clearance
a: 5.0-7.0 mm {0.20-0.27 in}
b: -2.0-0 mm {-0.07-0 in}
c: 3.5-6.5 mm {0.1-0.25 in}
d: -1.7-0.7 mm {-0.067-0.027 in}
e: 4.0-8.0 mm {0.16-.31 in}

3. Tighten the nuts or bolts.

LIFTGATE STAY DAMPER DISPOSAL
1. Referring to procedures for trunk lid stay damper disposal, dispose of the liftgate stay damper.