Oscilloscope Patterns and Waveforms
INSPECTION USING AN OSCILLOSCOPE (REFERENCE)Shift Solenoid A signal
PCM Terminals
- 1B (+) - Negative battery terminal (-)
Oscilloscope setting
- 5 V/DIV (Y), 5 ms/DIV (X), DC range
Vehicle condition
- 4GR
Shift solenoid B signal
PCM terminals
- 1C (+) - Negative battery terminal (-)
Oscilloscope setting
- 5 V/DIV (Y), 5 ms/DIV (X), DC range
Vehicle condition
- 1GR
Shift solenoid C signal
PCM terminals
- 1 D (+) - Negative battery terminal (-)
Oscilloscope setting
- 5 V/DIV (Y), 5 ms/DIV (X), DC range
Vehicle condition
- 1GR or 2GR