Oscilloscope Patterns and Waveforms
INSPECTION USING AN OSCILLOSCOPE (REFERENCE)Input/turbine speed sensor (+) signal
PCM terminals
- 1 M (+) - Negative battery terminal (-)
Oscilloscope setting
- 500 mV/DIV (Y), 1 ms/DIV (X), DC range
Vehicle condition
- Idle after warm-up
Input/turbine speed sensor (-) signal
PCM terminals
- 1Q (+) - Negative battery terminal (-)
Oscilloscope setting
- 500 mV/DIV (Y), 1 ms/DIV (X), DC range
Vehicle condition
- Idle after warm-up