Except California Emission Regulation Applicable ATX Model
Inspection Using An Oscilloscope (Reference) (Except for California emission regulation applicable ATX model)CMP sensor signal
(+)
- PCM terminals: 2J(+) - 2H(-)
- Oscilloscope setting: 1 V/DIV (Y), 10 ms/DIV (X), DC range
- Vehicle condition: Idle after warm up (engine speed approx. 700 rpm, no load, P/S off, A/C off)
(-)
- PCM terminals: 2M(+) - 2H(-)
- Oscilloscope setting: 1 V/DIV (Y), 10 ms/DIV (X), DC range
- Vehicle condition: Idle after warm up (engine speed approx. 700 rpm, no load, P/S off, A/C off)