Operation CHARM: Car repair manuals for everyone.

Main Relay Operation Inspection

Main Relay Operation Inspection

1. Verify that the main relay clicks when the ignition switch is turned to ON position and off.
- If there is no operation sound, inspect the following:
- Main relay
- Harness and connector between ignition switch and main relay terminal A.
- Harness and connector between PCM terminal 46*1, 2X*2 and main relay terminal E.

*1 : California emission regulation applicable ATX model
*2 : Except for California emission regulation applicable ATX model