Operation CHARM: Car repair manuals for everyone.

Oscilloscope Patterns and Waveforms

Inspection Using An Oscilloscope (Reference)

CMP sensor signal




(+)
- PCM terminals
- CMP sensor (left bank): 80 (+) - 26 (-)
- CMP sensor (right bank): 28 (+) - 26 (-)

- Oscilloscope setting
- 1 V/DIV (Y), 20 ms/DIV (X), DC range

- Vehicle condition
- Idle after warm up (no load)




(-)
- PCM terminals
- CMP sensor (left bank): 54 (+) - 26 (-)
- CMP sensor (right bank): 2 (+) - 26 (-)

- Oscilloscope setting
- 1 V/DIV (Y), 20 ms/DIV (X), DC range

- Vehicle condition
- Idle after warm up (no load)