Control Module HVAC: Testing and Inspection
A/C AMPLIFIER INSPECTION1. Turn the ignition switch to the ON position
2. Connect the negative (-) lead of the tester to body ground
Terminal Voltage Table (Reference) Part 1:
Terminal Voltage Table (Reference) Part 2:
Terminal Voltage Table (Reference) Part 3:
3. By inserting the positive (+) lead of the tester into each A/C amplifier terminal, measure the voltage according to the terminal voltage table.
- If there is any malfunction, inspect the parts under "Inspection item(s)".
- If the parts under "Inspection item(s)" are found to be normal, replace the A/C amplifier.