Control Module HVAC: Testing and Inspection
PWM UNIT INSPECTION1. Connect the PWM unit connector.
2. Turn the ignition switch to ON position.
3. Measure the voltage at each PWM unit terminal and refer to the terminal voltage list.
- If not as specified, inspect the parts listed under "Action" and the related wiring harness.