Variable Intake Air Shutter Valve Actuator Inspection
VARIABLE INTAKE AIR SHUTTER VALVE ACTUATOR INSPECTION1. Remove the air hose. (See INTAKE AIR SYSTEM REMOVAL/INSTALLATION.)
2. Disconnect the vacuum hose from the Variable intake air control solenoid valve.
3. Connect a vacuum pump to the Variable intake air shutter valve actuator.
4. Apply vacuum and verify that the rod moves.
- If the rod dose not move, replace the intake manifold.