Operation CHARM: Car repair manuals for everyone.

Field Coil: Testing and Inspection

Generator field coil control signal




- PCM terminals: 2AI(+)-body ground(-)
- Oscilloscope setting: 0.5 V/DIV (Y), 1 minute/DIV (X), DC range
- Vehicle condition: Idle after warm up (no load, P/S off, A/C off)