Programming and Relearning
INSTRUMENT CLUSTER CONFIGURATION1. Connect the M-MDS to the DLC-2.
2. After set up the M-MDS (including the vehicle recognition), the following can be selected from the M-MDS screen.
When using the IDS (laptop PC):
- "Module Programming"
When using the PDS (Pocket PC):
- "Programming", "Module Programming"
3. Select "Programmable Module Installation".
4. Select "IC" and perform procedures according to directions on the M-MDS screen.
- If odometer data is to be transferred to a new instrument cluster, perform the following procedure:
1. Select "Programmable Parameters" from the menu.
2. Select "Odometer Write", and perform the procedure following the screen.
NOTE: During the odometer data writing procedure, As-Built Data (VIN and Vehicle Data) input is requested. Obtain the As-Built Sheet for the vehicle, and input the necessary data.
5. After the instrument cluster configuration, perform the wheel unit ID registration. (See WHEEL UNIT ID REGISTRATION.)
6. Retrieve DTCs using the M-MDS and verify that there is no DTC present.
- If any DTC is present, perform applicable DTC inspection. (See DTC TABLE (INSTRUMENT CLUSTER).) Diagnostic Trouble Code Descriptions