TCM Inspection
TCM INSPECTION [SJ6A-EL]Terminal Voltage Table (Reference)
Note:
^ Use the ground of terminal 1P and 1 X of the TCM when measuring terminal voltage, as an error may occur when connecting the negative circuit tester to ground.
Inspection Using An Oscilloscope (Reference) Turbine sensor
^ TCM terminal: 2A
^ Oscilloscope setting: 5 V/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: Vehicle speed at 30 km/h (19 mph) (D range 1GR)
Vehicle speed
^ TCM terminal: 2D
^ Oscilloscope setting: 5 V/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: Vehicle speed at 30 km/h (19 mph) (D range 1GR)
Shift solenoid F control
^ TCM terminal: 1Z
^ Oscilloscope setting: 5 V/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: D range 5GR
Shift solenoid F control
^ TCM terminal: 1O
^ Oscilloscope setting: 200 mV/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: D range 5GR
Shift solenoid G, control
^ TCM terminal: 1Y
^ Oscilloscope setting: 5 V/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: D range 1GR
Shift solenoid G control
^ TCM terminal: 1L
^ Oscilloscope setting: 100 mV/DIV (Y) 1ms/DIV (X)
^ Measuring condition: D range 3GR-> 4GR
TCC control solenoid control
^ TCM terminal: 1Q
^ Oscilloscope setting: 50 mV/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: P, N position, Idle
TCC control solenoid control
^ TCM terminal: 1D
^ Oscilloscope setting: 50 mV/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: P, N position, Idle
Line pressure control solenoid control
^ TCM terminal: 1R
^ Oscilloscope setting: 5 V/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: P, N position, Idle
Line pressure control solenoid control
^ TCM terminal: 1E
^ Oscilloscope setting: 100 mV/DIV (Y) 1 ms/DIV (X)
^ Measuring condition: P, N position, Idle