Power Door Lock Actuator: Testing and Inspection
DOOR LOCK ACTUATOR INSPECTION[ADVANCED KEYLESS SYSTEM]Door Lock Actuator
1. Disconnect the door lock actuator connector.
2. Apply battery positive voltage and connect the ground to the corresponding door lock actuator terminals and inspect the door lock actuator operation.
- If not as specified, replace the door lock actuator.
Door Lock-link Switch
1. Disconnect the door lock actuator connector.
2. Inspect for continuity between the door lock-link switch terminals.
- If not as specified, replace the door lock actuator.
Door Key Cylinder Switch
1. Disconnect the door lock actuator connector.
2. Inspect for continuity between the door lock-link switch terminals.
- If not as specified, replace the door lock actuator.