Convertible Top Control Module: Testing and Inspection
POWER RETRACTABLE HARDTOP CONTROL MODULE INSPECTION1. Remove the following parts:
1. Console
2. Quarter trim
3. Scuff plate
4. Tire house trim
5. Aeroboard
6. Front seat back bar garnish
7. Back trim
2. Attach the tester lead to the power retractable hardtop control module wiring harness-side connector and inspect voltage, continuity, or resistance according to the standard (reference) on the table.
* 1. : The voltage increases during operation speed control of the roof and deck panel.
Inspection using an oscilloscope (reference) Roof motor hall sensor
- Terminal connected: power retractable hardtop control module 1I (RH), 1M (LH)
- Negative battery terminal
- Oscilloscope setting: 2 V/DIV (Y): 5 ms/DIV (X), DC range
- Measurement condition: When the roof is moving.
NOTE: Pulse interval varies with the roof operation speed.
Deck panel motor hall sensor
- Terminal connected: power retractable hardtop control module 1K (RH), 10 (LH)-Negative battery terminal
- Oscilloscope setting: 2 V/DIV (Y): 5 ms/DIV (X), DC range
- Measurement condition: When the deck panel is moving.
NOTE: Pulse interval varies with the deck panel operation speed.