Oscilloscope Patterns and Waveforms
Step 1:
Fuel injection signals
PCM terminals
- Fuel Injection No.1: 2BB (+)-Negative battery terminal (-)
- Fuel Injection No.2: 2BC (+)-Negative battery terminal (-)
- Fuel Injection No.3: 2BD (+)-Negative battery terminal (-)
- Fuel Injection No.4: 2AZ (+)-Negative battery terminal (-)
Oscilloscope setting
- 10 V/DIV (Y), 10 ms/DIV (X), DC range Vehicle condition
- Idle after warm-up