Power Window Main Switch Inspection [Power Retractable Hardtop]
POWER WINDOW MAIN SWITCH INSPECTION [POWER RETRACTABLE HARDTOP]With Exterior Open function
1. Measure the voltage at each terminal (other than terminals 1G, 1H, 2B and 2C).
- If the voltage is not as specified in the Terminal Voltage Table, inspect the parts under "inspection item (s)" and related wiring harnesses.
2. Disconnect the negative battery cable.
3. Inspect the power window main switch connector for continuity at terminal 1G.
Terminal 1A - 2B:
4. If the system does not work properly even though the inspection items or related wiring harnesses do not have any malfunction, replace the power window main switch.
Without Exterior Open function
1. Measure the voltage at each terminal (other than terminals A, H and G).
- If the voltage is not as specified in the Terminal Voltage Table, inspect the parts under "inspection item (s)" and related wiring harnesses.
2. Disconnect the negative battery cable.
3. Inspect the power window main switch connector for continuity at terminal G.
Terminal B - H:
4. If the system does not work properly even though the inspection items or related wiring harnesses do not have any malfunction, replace the power window main switch.