Auxiliary Port Valve (APV) Motor Inspection (138-MSP (High Power))
AUXILIARY PORT VALVE (APV) MOTOR INSPECTION (13B-MSP (HIGH POWER))Resistance Inspection
1. Remove the APV motor.
2. Measure the resistance between the APV motor terminals using an ohmmeter.
- If not as specified, replace the APV motor.
- If as specified, carry out the "Circuit Open/ Short Inspection".
APV motor resistance
8-50 ohms
Operation Inspection
CAUTION: Applying voltage to the APV motor terminals for more than 3 s may damage the APV motor.
1. Disconnect the negative battery cable.
2. Remove the APV motor.
3. Apply 12 V with a current of 0.9-1.9 A to terminal B or D and verify that the gear moves.
- If there is no malfunction, carry out the "Circuit Open/Short Inspection".
- If there is any malfunction, replace the APV motor.
Circuit Open/Short Inspection
1. Inspect the given wiring harnesses for an open, or short circuit. (Continuity check)
Open circuit
- If there is no continuity, the circuit is open. Repair or replace the wiring harness.
- APV motor terminal B and PCM terminal 3J
- APV motor terminal D and PCM terminal 3G
Short circuit
- If there is continuity, the circuit is shorted. Repair or replace the wiring harness.
- APV motor terminal B and power supply
- APV motor terminal B and body GND
- APV motor terminal D and power supply
- APV motor terminal D and body GND