[RC4A-El] Automatic Transmission/Transaxle
PID/DATA MONITOR INSPECTION [RC4A-EL]1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initial screen of the M-MDS.
^ When using the IDS (laptop PC)
1. Select the "Toolbox" tab.
2. Select "DataLogger".
3. Select "Modules".
4. Select "TCM".
^ When using the PDS (Pocket PC)
1. Select "Module Tests".
2. Select "TCM".
3. Select "DataLogger".
3. Select the PID from the PID table
4. Verify the PID data according to the directions on the M-MDS screen.
5. Connect the M-MDS to the DLC-2.
6. Measure the PID value.
Note:
^ Perform part inspection for the output device after TCM inspection.
^ The PID/DATA MONITOR function monitors the calculated value of the input/output signals in the TCM. Therefore, if a monitored value of an output device is not within specification, it is necessary to inspect the monitored value of the input device related to the output device control. Since an output device malfunction is not directly indicated as a malfunction of the monitored value for the output device, it is necessary to inspect the output device individually using the simulation function.