Instrument Cluster Configuration
INSTRUMENT CLUSTER CONFIGURATIONNOTE:
- If all the following conditions are met, the odometer data (total traveled distance) in the previous instrument cluster is automatically transferred to a new instrument cluster during the configuration. If any of the conditions are not met, odometer-data transfer cannot be performed.
Previous instrument cluster
- No malfunction (Configuration data can be read using the M-MDS.)
New instrument cluster
- Odometer display is less than 100 km
- Odometer has no malfunction
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
1. Select "Module Programming".
- When using the PDS (Pocket PC)
1. Select "Programming".
2. Select "Module Programming".
3. Then, select items from the screen menu in the following order.
1. Select "Programmable Module Installation".
2. Select "IC".
4. Perform the configuration according to the directions on the screen.
If odometer data is to be transferred a new instrument cluster, perform the following procedure:
1. Select "Programmable Parameters" from the menu.
2. Select "Odometer Write", and perform the procedure following the screen.
NOTE: During the odometer data writing procedure, As-Built Data (VIN and Vehicle Data) input is requested. Obtain the As-Built Sheet for the vehicle, and input the necessary data.
5. Retrieve DTCs by the M-MDS, then verify that there is no DTC present.
- If a DTC (s) is detected, perform the applicable DTC inspection. (See DTC TABLE [INSTRUMENT CLUSTER].) DTC Table [Instrument Cluster]