Procedures
SECURITY ACCESS PROCEDURE [ADVANCED KEYLESS SYSTEM]1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
1. Select "Body".
2. Select "Security".
- When using the PDS (Pocket PC)
1. Select "Programming".
2. Select "PATS Functions".
3. Select the items to be performed from the following:
- Program Additional card key
- Card Key Code Erase and Program
- Steering Lock Unit Programming
- Program additional ignition key (with immobilizer system)
- Ignition Key Code Erase and Program (with immobilizer system)
- Customer Spare Key Programming Enable (with immobilizer system)
- Customer Spare Key Programming Disable (with immobilizer system)
4. The security access begins and the M-MDS displays the "OUT-CODE".
NOTE: When "OUT-CODE" is first displayed, turning the ignition switch from the LOCK to the ON position 5 times will change the "OUT-CODE".
5. Input "IN-CODE" corresponding to "OUT-CODE" displayed on the M-MDS screen.
6. If the security access is successful, selected item can be performed.