No.6 Security Access Procedure

No.6 Security Access Procedure

NOTE: Security access must be performed when performing the following functions: "Program additional ignition key", "Ignition Key Code Erase and Program", "Customer Spare Key Programming Enable/Disable" and "Parameter Reset".

Procedure
1. Connect the M-MDS to the DLC-2.
2. Select "Body/Security/PATS function" from the M-MDS screen menu.
3. Security access is started and the M-MDS displays "Outcode".

CAUTION: After reading out the outcode, do not turn ignition switch from LOCK to ON position 5 times, otherwise the outcode value will be changed.

4. Input the corresponding "Incode" for the "Outcode" displayed on the M-MDS screen.
5. After successfully performing security access, "Program additional ignition key", "Ignition Key Code Erase and Program" or "Customer Spare Key Programming Enable/Disable" is displayed on the M-MDS screen. When performing "Parameter Reset", security access is requested two times and after successfully performing it the second time, "Replacement Module" is displayed.