Main Relay Operation Inspection

Main Relay Operation Inspection

1. Verify that the main relay clicks when the ignition switch is turned to ON position and off.
- If there is no operation sound, inspect the following:
- Main relay (See RELAY INSPECTION.)
- Harness and connector between battery and main relay terminal A.
- Harness and connector between PCM terminal 10 and main relay terminal E.