Installation
Installation1. Assemble the SSTs so that dimension L is as specified.
Standard valve guide projection height
IN: 12.2-12.8 mm (0.481-0.503 in)
EX: 12.2-12.8 mm (0.481-0.503 in)
2. Tap the valve guide in from the cam side using the SSTs assembled in Step 1.