Operation CHARM: Car repair manuals for everyone.

Programming and Relearning




INSTRUMENT CLUSTER CONFIGURATION

NOTE:
- If all the following conditions are met, the odometer data (total traveled distance) in the previous instrument cluster is automatically transferred to a new instrument cluster during the configuration. If any of the conditions are not met, odometer-data transfer cannot be performed.

Previous instrument cluster
- No malfunction (Configuration data can be read using the M-MDS.)

New instrument cluster
- Odometer display is less than 100 km
- Odometer has no malfunction

1. Connect the M-MDS to the DLC-2.






2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.

- When using the IDS (laptop PC)

1 Select "Module Programming".

- When using the PDS (Pocket PC)

1 Select "Programming".
2 Select "Module Programming".

3. Select "Programmable Module Installation".

4. Select "IC" and perform procedures according to directions on the M-MDS screen.

- If odometer data is to be transferred to a new instrument cluster, perform the following procedure:

- Select "Programmable Parameters" from the menu.
- Select "Odometer Write", and perform the procedure following the screen.
NOTE:
- During the odometer data writing procedure, As-Built Data (VIN and Vehicle Data) input is requested. Obtain the As-Built Sheet for the vehicle, and input the necessary data.

5. Retrieve DTCs using the M-MDS and verify that there is no DTC present.

- If any DTC is present, perform applicable DTC inspection. DTC Table Instrument Cluster