Programming and Relearning
IMMOBILIZER SYSTEM COMPONENT REPLACEMENT/KEY ADDITION AND CLEARING [KEYLESS ENTRY SYSTEM]
Foreword
- When performing the following procedures, the immobilizer resetting procedure using the M-MDS must also always be performed: "instrument cluster replacement", "PCM replacement", "instrument cluster and PCM joint replacement", "Key ID number clearing". The engine will not start unless all work is performed using the M-MDS.
- There are two methods for registering an additional key: Using the M-MDS and using two keys that are able to start the engine.
- When replacing any of the immobilizer system component parts, adding/erasing keys or performing other functions, refer to the following table and perform the applicable procedure (No.1 to 5).
CAUTION:
- If any of the following items are touching or near the key head, signal communication between the key and vehicle is negatively affected, resulting in the engine not starting or the key registration failure. Do not perform the procedure if any of the following items are touching or near the key head.
- Any metallic object
- Spare keys or keys for other vehicles equipped with an immobilizer system
- Any electronic device, or any credit or other cards with magnetic strips
NOTE:
- Within the following procedures, the term a "valid key" means a "key that can start the engine".
- After adding/registering keys, clearing ID numbers or replacing any component part of the immobilizer system, verify that all keys can start the engine within 5 s.
- When verifying that the keys can start the engine, wait at least 5 s or more between inserting them.
- If the engine cannot be started using a registered key, repeat the procedure from the beginning.
- Do not start the engine until the key registration procedure for all the necessary keys is completed. If the engine is started during the registration procedure, registration is stopped at that point. Repeat the procedure starting from the beginning if the engine is started before completion.
- Two or more key ID numbers must be registered for the engine to start.
- A maximum of eight key ID numbers can be registered for one vehicle. The M-MDS can be used to verify the number of key ID numbers registered to a single vehicle.
- Do not select screen menus of the M-MDS that are not indicated within the procedures.
No.1 Additional Key Registration Procedure (Using Two Valid Keys)
Conditions
- Customer has two or more valid keys.
NOTE:
- A maximum of eight keys can be registered for any one vehicle. If key registration is not successful and DTC 15 appears even though the procedure was performed properly, use the PID/data monitor function of the M-MDS and verify the number of keys that have been registered.
- If eight keys have already been registered, and it is necessary to register other keys, the previously registered key ID numbers must first be cleared. To clear the key ID numbers, refer to "No.3 Key Replacement Procedure (Clearing Previously Registered Key ID Numbers , Key Re-registration)".
Procedure
1. Have one key (key 3) ready for registration.
2. Using key 1, turn the ignition switch to the ON position.
3. Verify that the security light illuminates for approx. 3 s and then goes out.
4. Using key 1, turn the ignition switch to the LOCK position within approx. 4 s after the security light goes out.
5. Remove key 1
6. Repeat Steps 2-5 using key 2.
7. Repeat Steps 2-5 using key 3.
8. If additional keys need to be registered, repeat Steps 1-7 in the same manner as key 3.
No.2 Additional Key Registration Procedure (Using the M-MDS)
Conditions
- Customer has only one valid key. Or customer has no valid keys. (Can also be performed even if there are two or more valid keys)
NOTE:
- A maximum of eight keys can be registered for any one vehicle. If key registration is not successful and DTC 15 appears even though the procedure was performed properly, use the PID/data monitor function of the M-MDS and verify the number of keys that have been registered.
- If eight keys have already been registered, and it is necessary to register other keys, the previously registered key ID numbers must first be cleared. To clear the key ID numbers, refer to No.3 Key Replacement Procedure (Clearing Previously Registered Key ID Numbers, Key Re-registration).
Procedure
1. Have one key (key 1) ready for registration.
2. Using key 1, turn the ignition switch to the ON position.
NOTE:
- Although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
3. Connect the M-MDS to the DLC-2.
4. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
1 Select the "Body".
2 Select the "Security".
3 Select the "PATS Functions".
- When using the PDS (Pocket PC)
1 Select the "Programming".
2 Select the "PATS Functions".
5. Then, select an item from the screen menu. "Program Additional ignition key".
6. Perform security access as indicated on the M-MDS screen. (see No.6 Security Access Procedure.)
7. Perform the procedure according to the directions on the screen.
No.3 Key Replacement Procedure (Clearing Previously Registered Key ID Numbers, Key Re-registration)
Procedure
1. Have two or more keys (key 1, key 2) ready for registration after the clearing the key ID numbers.
2. Using key 1, turn the ignition switch to the ON position.
NOTE:
- Although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
3. Connect the M-MDS to the DLC-2.
4. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
1 Select the "Body".
2 Select the "Security".
3 Select the "PATS Functions".
- When using the PDS (Pocket PC)
1 Select the "Programming".
2 Select the "PATS Functions".
5. Then, select an item from the screen menu. "Ignition Key Code Erase and Program".
6. Perform security access as indicated on the M-MDS screen. (see No.6 Security Access Procedure.)
7. Perform the procedure according to the directions on the screen.
No.4 Changing the Method for Registering Additional Keys
NOTE:
- This procedure is for changing the enable/disable setting of the "No.1 Additional Key Registration Procedure (Using Two Valid Keys)".
- The default setting for new vehicles and new instrument cluster replacement is "Enabled".
- By disabling the "No.1 Additional Key Registration Procedure (Using Two Valid Keys)", only the M-MDS can be used to register additional keys, thereby preventing two valid keys from being used to create an unauthorized spare key. This function is for use by rental car or other companies with vehicle fleets.
Procedure
1. Using any key, turn the ignition switch to the ON position. (Either a valid or an unregistered key can be used.)
NOTE:
- When using an unregistered key, although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
2. Connect the M-MDS to the DLC-2.
3. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
1 Select the "Body".
2 Select the "Security".
3 Select the "PATS Functions".
- When using the PDS (Pocket PC)
1 Select the "Programming".
2 Select the "PATS Functions".
4. Then, select an item from the screen menu. "Customer Spare Key Programming Enable" or "Customer Spare Key Programming Disable".
5. Perform the procedure according to the directions on the screen.
6. Perform security access as indicated on the M-MDS screen. (see No.6 Security Access Procedure.)
7. Select either "Customer Spare Key Programming Enable" or "Customer Spare Key Programming Disable" from the M-MDS screen menu. Depending on the selected menu, the additional key registration method is as shown below:
x
Procedure is possible
-
Procedure is not possible
8. After verifying that the PATS function menu is displayed again on the M-MDS screen, select "Exit" to complete the M-MDS function.
9. After Step 9, wait 10 s or more and then turn the ignition switch to the LOCK position.
No.5 Resetting Procedure for the Immobilizer System when Replacing the PCM or Instrument Cluster
Conditions
- When replacing only the PCM: No conditions.
- When replacing only the instrument cluster: Customer has two or more valid keys after replacement tasks.
- When replacing the PCM and the instrument cluster: Customer has two or more valid keys after replacement.
CAUTION:
- When replacing the PCM and the instrument cluster at the same time, follow the same instructions described in the procedure for "when replacing the instrument cluster".
- When replacing only the PCM, start from Step 2. Also, when key 1 is indicated within the procedure, any valid key can be used.
- Before starting Step 1, complete the procedure for PCM and instrument cluster replacement.
Procedure
1. Have two or more keys (key 1, key 2) ready for registration.
2. Using key 1, turn the ignition switch to the ON position.
NOTE:
- When replacing only the PCM: The security light illuminates for 3 s and then goes out.
- When replacing the instrument cluster: Although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
3. Connect the M-MDS to the DLC-2.
4. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
1 Select the "Body".
2 Select the "Security".
3 Select the "PATS Functions".
- When using the PDS (Pocket PC)
1 Select the "Programming".
2 Select the "PATS Functions".
5. Select "Ignition Key Code Erase" from the M-MDS screen menu and perform the procedure according to the M-MDS screen. (When replacing the instrument cluster)
6. Perform security access as indicated on the M-MDS screen. (see No.6 Security Access Procedure.)
7. Select "Parameter Reset" from the M-MDS screen menu.
8. Select the replaced part as indicated on the M-MDS screen.
- When replacing only the PCM: Select "PCM".
- When replacing only the instrument cluster: Select "IC".
NOTE:
- At this time, do not select any other parts from the M-MDS screen menu.
9. After verifying that the PATS function menu is displayed again on the M-MDS screen, select "Exit" to complete the M-MDS function.
10. After Step 9, wait 10 s or more and turn the ignition switch to the LOCK position using key 1.
11. Using key 1, turn the ignition switch to the ON position.
NOTE:
- When replacing only the PCM: The security light illuminates for 3 s and then goes out.
- When replacing only the instrument cluster: Although the security light flashes and DTC 21 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
12. Perform the following procedures:
- When replacing only the PCM: After verifying that the security light goes out, turn the ignition switch to the LOCK position. (Procedure completed)
- When replacing only the instrument cluster: After verifying that the security light illuminates for 3 s or more, turn the ignition switch to the LOCK position, remove key 1, and then go to the next step.
13. Using key 2, turn the ignition switch to the ON position.
14. Verify that the security light illuminates for approx. 3 s and then goes out.
15. After verifying that the security light goes out, turn the ignition switch to the LOCK position using key 2, and then remove key 2.
16. If an additional key needs to be registered, repeat Steps 13-15 in the same manner as key 2. Steps 13-15 must be performed within 1 min for each key. If the ignition switch is maintained in the ON position for 1 min or more, key registration according to Steps 13-15 will not be possible. If this occurs, refer to "No.1 Additional Key Registration Procedure (Using Two Valid Keys)" to register any additional keys.
No.6 Security Access Procedure
NOTE:
- Security access must be performed when performing the following functions: "Program Additional ignition key", "Ignition Key Code Erase and Program", "Customer Spare Key Programming Enable/Disable" and "Parameter Reset".
Procedure
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
1 Select the "Body".
2 Select the "Security".
3 Select the "PATS Functions".
- When using the PDS (Pocket PC)
1 Select the "Programming".
2 Select the "PATS Functions".
3. Then, select items from the screen menu in the following order.
- Program additional ignition key
- Ignition Key Code Erase and Program
- Customer Spare Key Programming Enable
- Customer Spare Key Programming Disable
- Parameter Reset
4. The security access begins and the M-MDS displays the "OUT-CODE".
NOTE:
- When "OUT-CODE" is first displayed, turning the ignition switch from the LOCK to the ON position 5 times will change the "OUT-CODE".
5. Input "IN-CODE" corresponding to "OUT-CODE" displayed on the M-MDS screen.
6. If the security access is successful, selected item can be performed.