Keyless Beeper Inspection [Advanced Keyless Entry And Push Button Start System]
KEYLESS BEEPER INSPECTION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM]
1. Disconnect the negative battery cable.
2. Remove the keyless beeper. Keyless Beeper Removal/Installation [Advanced Keyless Entry And Push Button Start System]
3. Apply battery positive voltage and connect the ground to each terminal and verify the keyless beeper sound operation.
- If the beep sound cannot be verified, replace the keyless beeper.