Variable Induction Position Sensor: Testing and Inspection
VARIABLE TUMBLE SHUTTER VALVE SWITCH INSPECTION [L5]
1. Connect the M-MDS to the DLC-2.
2. Switch the ignition to ON.
3. Verify that the voltage (M-MDS PID: IMRC_POS) within the specification. Component Tests and General Diagnostics
- If not as specified, replace the intake manifold.
Service and Repair