On-Board System Readiness Tests Access Procedure
ON-BOARD DIAGNOSTIC TEST [MZI-3.7]
On-Board System Readiness Tests Access Procedure
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
- Select "Powertrain".
- Select "OBD Test Modes".
- Select "Mode 1 Powertrain Data".
- Select "PCM".
- When using the PDS (Pocket PC)
- Select "OBDII Modes".
- Select "Mode 1 Powertrain Data".
- Select "PCM".
3. Then, select the "***SUP" and "**EVAL" PIDs in the PID selection screen.
4. Monitor those PIDs and check it system monitor is completed.
NOTE:
- If the on-board system readiness tests are not completed the PCM stores DTC P1000:00.