B1013
DTC B1013
System Malfunction Location
B1013:
Detection Condition
WARNING:
- Detection conditions are for understanding the DTC outline before performing an inspection. Performing an inspection according to only the detection conditions may cause injury due to an operating error, or damage the system. When performing an inspection, always follow the inspection procedure.
- Calibration set value not within valid range.
Possible Causes
- Weight acting on passenger-side seat during calibration
- Improperly installed passenger-side seat part at time of calibration
- Deformed floor where attached to passenger-side seat
- Deformed passenger-side seat under-bracket or frame
- Seat weight sensor deformed or malfunction
- Seat weight sensor control module malfunction
- SAS control module malfunction
Diagnostic Procedure