Keyless Entry: Service and Repair
SECURITY ACCESS PROCEDURE
NOTE:
- Security access must be performed when performing the following functions: "Program Additional ignition key", "Ignition Key Code Erase and Program", "Customer Spare Key Programming Enable/Disable" and "Parameter Reset".
1. Connect the M-MDS to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
1 Select the "Body".
2 Select the "Security".
3 Select the "PATS Functions".
- When using the PDS (Pocket PC)
1 Select the "Programming".
2 Select the "PATS Functions".
3. Then, select items from the screen menu in the following order.
- Program additional ignition key
- Ignition Key Code Erase and Program
- Customer Spare Key Programming Enable
- Customer Spare Key Programming Disable
- Parameter Reset
4. The security access begins and the M-MDS displays the "OUT-CODE".
NOTE:
- When "OUT-CODE" is first displayed, turning the ignition switch from the LOCK to the ON position 5 times will change the "OUT-CODE".
5. Input "IN-CODE" corresponding to "OUT-CODE" displayed on the M-MDS screen.
6. If the security access is successful, selected item can be performed.