Fuel Pump: Testing and Inspection
FUEL PUMP UNIT INSPECTION [L3]
Fuel Pump Operation Inspection
1. Connect the M-MDS to the DLC-2.
2. Remove the fuel-filler cap. Service and Repair
3. Turn the ignition switch to the ON position.
4. Using the simulation function "FP", verify that operation sound is heard from the fuel pump when "FP" is turned from OFF to ON.
- If the operation sound cannot be verified, measure the voltage at fuel pump wiring harness-side connector terminal A.
- If as specified, inspect the following:
- Fuel pump continuity
- If not within the specification, inspect the following:
- Fuel pump relay
- Wiring harnesses and connectors between main relay-fuel pump relay-fuel pump
Standard
- B+ (Ignition switch at ON)
Continuity Inspection
1. Remove the battery cover. Removal and Replacement
2. Disconnect the negative battery cable.
3. Disconnect the fuel pump unit connector.
4. Inspect for continuity between fuel pump unit terminals B-D.
- If there is continuity, perform the "Circuit Open/Short Inspection".
- If there is no continuity, replace the fuel pump unit. Removal and Replacement
Circuit Open/Short Inspection
1. Inspect the following wiring harnesses for an open or short circuit (continuity check).
Open circuit
- If there is no continuity, the circuit is open. Repair or replace the harness.
- Fuel pump unit terminal B and fuel pump relay terminal C
- Fuel pump unit terminal D and body ground
Short circuit
- If there is continuity, the circuit is short. Repair or replace the harness.
- Fuel pump unit terminal B and body ground
- Fuel pump unit terminal D and power supply
Fuel Static Pressure Inspection
NOTE:
- The fuel static pressure inspection cannot be performed because the pressure regulator is integrated with the fuel pump unit.