Knock Sensor: Testing and Inspection
KNOCK SENSOR (KS) INSPECTION [L3]
Resistance Inspection
1. Disconnect the knock sensor connector.
2. Measure resistance between KS terminals A and B.
- If not within the specification, replace the KS.
- If the monitor item status/specification (reference) is not within the specification, even though the KS resistance is within the specification, perform the "Circuit Open/Short Inspection".
Resistance
- Approx. 4.87 megohms
Circuit Open/Short Inspection
1. Disconnect the PCM connector.
2. Inspect the following wiring harnesses for an open or short circuit. (Continuity inspection)
Open circuit
- If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
- Knock sensor terminal A and PCM terminal 2U
- Knock sensor terminal B and PCM terminal 2V
Short circuit
- If there is continuity, there is a short circuit. Repair or replace the wiring harness.
- Knock sensor terminal A and power supply
- Knock sensor terminal A and body ground
- Knock sensor terminal B and power supply
- Knock sensor terminal B and body ground