Neutral Safety Switch: Testing and Inspection
NEUTRAL SWITCH INSPECTION [L3]
Continuity Inspection
1. Remove the neutral switch. Service and Repair
2. Verify that the continuity between neutral switch terminals A and B is as indicated in the table.
- If there is no malfunction, perform the "Circuit Open/Short Inspection".
- If there is any malfunction, replace the neutral switch.
Circuit Open/Short Inspection
1. Disconnect the PCM connector.
2. Inspect the following wiring harness for an open or short circuit. (Continuity inspection)
Open circuit
- If there is no continuity in the following wiring harnesses, there is an open circuit. Repair or replace the wiring harness.
- Neutral switch terminal A and PCM terminal 1BC
- Neutral switch terminal B and body ground
Short circuit
- If there is continuity in the following wiring harnesses, there is a short circuit. Repair or replace the wiring harness.
- Neutral switch terminal A and power supply
- Neutral switch terminal A and body ground
- Neutral switch terminal B and power supply