Programming and Relearning
SEAT WEIGHT SENSOR CALIBRATION
CAUTION:
- If any of the following work is performed, perform the seat weight sensor calibration using the M-MDS.
- Replacement with a new seat weight sensor
- Replacement with a new seat weight sensor control module
- Replacement with new passenger-side seat parts
- Disassembly of the passenger-side seat
- If any of the following work is performed, perform the seat weight sensor inspection using the M-MDS. Component Tests and General Diagnostics
- Removal of the passenger-side seat
- Loosening and retightening of passenger's seat fixing bolts
- Or, the vehicle is involved in a collision
1. Have two 20 kg {44 lb} weights ready to use.
2. Connect the M-MDS to the DLC-2.
3. After the vehicle is identified, select the following items from the initialization screen of the M-MDS.
- When using the IDS (laptop PC)
- Select "Body".
- Select "Restraints".
4. Then, select item from the screen menu in the following order.
- Select "Passenger Seat Weight Sensor ReZero".
5. Perform calibration following the procedures on the M-MDS screen.