Gear Sensor/Switch: Testing and Inspection
NEUTRAL SWITCH INSPECTION [LF]
NOTE:
- Before performing the following inspection, make sure to follow the procedure as indicated in the troubleshooting flowchart. Description and Operation
Continuity Inspection
1. Remove the neutral switch. M15M-D
P66M-D
2. Verify that the continuity between neutral switch terminals 1A and 2A is as indicated in the table.
- If not as indicated in the table, replace the neutral switch. M15M-D P66M-D
- If the monitor item condition/specification (reference) is not within the specification, even though there is no malfunction, perform the "Circuit Open/Short Inspection".
Circuit Open/Short Inspection
1. Disconnect the PCM connector. Service and Repair
2. Inspect the following wiring harness for open or short circuit (continuity Inspection).
Open circuit
- If there is no continuity, there is an open circuit. Repair or replace the wiring harness.
- Neutral switch terminal 2A and PCM terminal 1X
- Neutral switch terminal 1A and body ground
Short circuit
- If there is continuity, there is a short circuit. Repair or replace the wiring harness.
- Neutral switch terminal 2A and body ground