Operation CHARM: Car repair manuals for everyone.

Manual Air Conditioner




BLOWER MOTOR INSPECTION [MANUAL AIR CONDITIONER]

1. Connect battery positive voltage to blower motor terminal A, ground to terminal B, and then verify that the blower motor operates smoothly.

- If the operation condition is not normal, replace the blower motor.