Fuel Pump: Testing and Inspection
FUEL PUMP UNIT INSPECTION [13B-MSP]
Continuity Inspection
1. Disconnect the negative battery cable.
2. Disconnect the fuel pump unit connector.
3. Inspect for continuity between fuel pump unit connector terminals B and D.
- If there is no continuity, replace the fuel pump unit. Removal and Replacement
- If as specified, carry out the "Circuit Open/Short Inspection".
Circuit Open/Short Inspection
1. Inspect the following wiring harnesses for open or short (continuity check).
Open circuit
- If there is no continuity, the circuit is open. Repair or replace the wiring harness.
- Fuel pump unit terminal D and body GND
- Fuel pump unit terminal B and main relay terminal C
Short circuit
- If there is no continuity, the circuit is shorted. Repair or replace the wiring harness.
- Fuel pump unit terminal D and power supply
- Fuel pump unit terminal B and body GND