Control Module: Testing and Inspection
PCM INSPECTION [FN4A-EL]
CAUTION:
- Water or foreign objects entering the connector can cause a poor connection or corrosion. Be sure not to drop water or foreign objects on the connector when disconnecting it.
NOTE:
- The PCM terminal voltage can vary with conditions when measuring and changes due to age deterioration on the vehicle, causing false diagnosis. Therefore a comprehensive inspection of the input and output systems, and the PCM is necessary to determine where the malfunction occurs.
1. Remove the PCM connector cover. PCM Removal/Installation
2. Connect the voltmeter (-) lead to body GND.
3. Measure the voltage at each terminal.
- If any incorrect voltage is detected, inspect the related system(s), wiring harnesses and connector(s) referring to the "Inspection Item" column in the "PCM Terminal Voltage".
PCM Terminal Voltage (Reference)
NOTE:
- Only the transaxle-related information is described.
Input/Output Wave From (Reference)
Shift solenoid A
PCM terminals
- 1D (+)-Negative battery terminal (-)
Oscilloscope setting
- 5 V/DIV (Y), 5 ms/DIV (X), DC range
Vehicle condition
- D position O/D
Shift solenoid B
PCM terminals
- 1H (+)-Negative battery terminal (-)
Oscilloscope setting
- 5 V/DIV (Y), 5 ms/DIV (X), DC range
Vehicle condition
- D position 1GR
Shift solenoid C
PCM terminals
- 1L (+)-Negative battery terminal (-)
Oscilloscope setting
- 5 V/DIV (Y), 5 ms/DIV (X), DC range
Vehicle condition
- D position 1GR
Pressure control solenoid (+)
PCM terminals
- 1P (+)-Negative battery terminal (-)
Oscilloscope setting
- 5 V/DIV (Y), 1 ms/DIV (X), DC range
Vehicle condition
- Idle at P position after warm-up
Pressure control solenoid (-)
PCM terminals
- 1T (+)-Negative battery terminal (-)
Oscilloscope setting
- 5 V/DIV (Y), 1 ms/DIV (X), DC range
Vehicle condition
- Idle at P position after warm-up
Input/turbine speed sensor
PCM terminals
- 1R (+)-1V (-)
Oscilloscope setting
- 1 V/DIV (Y), 2 ms/DIV (X), DC range
Vehicle condition
- Idle at P position after warm-up
VSS
PCM terminals
- 1AX (+)-Negative battery terminal (-)
Oscilloscope setting
- 1 V/DIV (Y), 2 ms/DIV (X), DC range
Vehicle condition
- The following conditions are met:
- Vehicle speed: 30 km/h {19 mph}
- Gear position: 3GR