Dynamic Stability Control (DSC)
Intermittent Concern Troubleshooting
Vibration method
- If malfunction occurs or becomes worse while driving on a rough road or when engine is vibrating, perform the steps below.
NOTE:
- There are several reasons why vehicle or engine vibration could cause an electrical malfunction. Some of the things to check for are:
- Connectors not fully seated.
- Wire harnesses not having full play.
- Wires laying across brackets or moving parts.
- Wires routed too close to hot parts.
- An improperly routed, improperly clamped, or loose harness can cause wiring to become pinched between parts.
- The connector joints, points of vibration, and places where wire harnesses pass through the firewall, body panels, etc. are the major areas to be checked.
Inspection method for switch connectors or wires
1. Connect the M-MDS to DLC-2.
2. Switch the ignition to ON (engine off).
NOTE:
- If engine starts and runs, perform the following steps at idle.
3. Access the PIDs for the switch you are inspecting.
4. Turn switch on manually.
5. Shake each connector or wire harness a bit vertically and horizontally while monitoring the PID.
- If the PID value is unstable, check for poor connection.
Inspection method for sensor connectors or wires
1. Connect the M-MDS to DLC-2.
2. Switch the ignition to ON (engine off).
NOTE:
- If engine starts and runs, perform the following steps at idle.
3. Access the PIDs for the switch you are inspecting.
4. Shake each connector or wire harness a bit vertically and horizontally while monitoring the PID.
- If the PID value is unstable, check for poor connection.
Inspection method for sensors
1. Connect the M-MDS to DLC-2.
2. Switch the ignition to ON (engine off).
NOTE:
- If engine starts and runs, perform the following steps at idle.
3. Access the PIDs for the switch you are inspecting.
4. Vibrate the sensor slightly with your finger.
- If the PID value is unstable or malfunction occurs, check for poor connection and/or poorly mounted sensor.
Malfunction data monitor method
1. Perform malfunction reappearance test according to malfunction reappearance mode and malfunction data monitor. The malfunction cause is found in the malfunction data.
Connector terminal check method
1. Check the connection condition of each female terminal.
2. Insert a male terminal to the female terminal and inspect the female terminal for looseness.