Manual Air Conditioner
BLOWER MOTOR INSPECTION [MANUAL AIR CONDITIONER]
1. Connect battery positive voltage to blower motor terminal A, connect terminal B to ground, and then verify its operation.
- If there is any malfunction, replace the blower motor.